CASE STUDIES

ULTRASOUND

Vacuum Leak Detection in an RH Degasser | Steel Plant
Vacuum Leak Detection in an RH Degasser | Steel Plant | Figure 1
Vacuum Leak Detection in an RH Degasser | Steel Plant | Figure 1
Vacuum Leak Detection in an RH Degasser | Steel Plant | Figure 2
Vacuum Leak Detection in an RH Degasser | Steel Plant | Figure 2
Vacuum Leak Detection in an RH Degasser | Steel Plant | Figure 3
Vacuum Leak Detection in an RH Degasser | Steel Plant | Figure 3
Vacuum Leak Detection in an RH Degasser | Steel Plant | Figure 4
Vacuum Leak Detection in an RH Degasser | Steel Plant | Figure 4

An RH degasser removes dissolved gases such as hydrogen from molten steel. This case documents vacuum leak inspection on the RH degasser, a secondary refining system used in high-grade steel production.

Compressed Air Leak Detection | Power Plant
Compressed Air Leak Detection | Power Plant | Figure 1
Compressed Air Leak Detection | Power Plant | Figure 1

This case documents a compressed-air leak inspection at a power plant.

NITROGEN GAS LEAKS PRODUCES TURBULENCE AND CAN BE DETECTED BY ULTRAPROBE
Nitrogen Gas Leak Detection with Ultraprobe | Figure 1
Nitrogen Gas Leak Detection with Ultraprobe | Figure 1
Nitrogen Gas Leak Detection with Ultraprobe | Figure 2
Nitrogen Gas Leak Detection with Ultraprobe | Figure 2
Nitrogen Gas Leak Detection with Ultraprobe | Figure 3
Nitrogen Gas Leak Detection with Ultraprobe | Figure 3

Nitrogen is used for purging and controlled processing in pharmaceutical and active pharmaceutical ingredient plants. The case illustrates using ultrasound to detect turbulence from a nitrogen leak.

Know When to Lubricate & How Much To Lubricate | Cement,
Ultrasound-Guided Lubrication | Cement Plant | Figure 1
Ultrasound-Guided Lubrication | Cement Plant | Figure 1
Ultrasound-Guided Lubrication | Cement Plant | Figure 2
Ultrasound-Guided Lubrication | Cement Plant | Figure 2
Ultrasound-Guided Lubrication | Cement Plant | Figure 3
Ultrasound-Guided Lubrication | Cement Plant | Figure 3
Ultrasound-Guided Lubrication | Cement Plant | Figure 4
Ultrasound-Guided Lubrication | Cement Plant | Figure 4

This case covers lubrication monitoring on the non-drive-end bearing of a high-tension motor.

Valve Internal Passing Inspection
Valve Internal Passing Inspection | Figure 1
Valve Internal Passing Inspection | Figure 1

The inspection compares ultrasound readings at points A through D to assess internal valve passing and distinguish it from downstream turbulence. The source includes an additional point E when the downstream reading is highest.

Steam Trap Inspection | Pharma Plant
Steam Trap Inspection | Pharmaceutical Plant | Figure 1
Steam Trap Inspection | Pharmaceutical Plant | Figure 1
Steam Trap Inspection | Pharmaceutical Plant | Figure 2
Steam Trap Inspection | Pharmaceutical Plant | Figure 2

The inspection report illustrates how identifying steam losses can support boiler efficiency, reduce fuel and water consumption, and inform predictive maintenance.

Condition Monitoring Case Study | Cement Plant
Condition Monitoring Case Study | Cement Plant | Figure 1
Condition Monitoring Case Study | Cement Plant | Figure 1
Condition Monitoring Case Study | Cement Plant | Figure 2
Condition Monitoring Case Study | Cement Plant | Figure 2
Condition Monitoring Case Study | Cement Plant | Figure 3
Condition Monitoring Case Study | Cement Plant | Figure 3

The source document presents these inspection images from a cement manufacturing plant.

Bearing Outer Race Fault | Paper Plant
Bearing Outer Race Fault | Paper Plant | Figure 1
Bearing Outer Race Fault | Paper Plant | Figure 1
Bearing Outer Race Fault | Paper Plant | Figure 2
Bearing Outer Race Fault | Paper Plant | Figure 2
Bearing Outer Race Fault | Paper Plant | Figure 3
Bearing Outer Race Fault | Paper Plant | Figure 3

The FFT and time waveform showed peaks and impacts that matched the bearing outer-race fault frequency. Inspection after disassembly revealed a crack in the bearing.

Inspection Case Study | Steel Plant
Inspection Case Study | Steel Plant | Figure 1
Inspection Case Study | Steel Plant | Figure 1
Inspection Case Study | Steel Plant | Figure 2
Inspection Case Study | Steel Plant | Figure 2
Inspection Case Study | Steel Plant | Figure 3
Inspection Case Study | Steel Plant | Figure 3

The source document presents these inspection images from a steel plant.

2AG-2321 PTA First Crystallizer Agitator
2AG-2321 PTA First Crystallizer Agitator | Figure 1
2AG-2321 PTA First Crystallizer Agitator | Figure 1
2AG-2321 PTA First Crystallizer Agitator | Figure 2
2AG-2321 PTA First Crystallizer Agitator | Figure 2
2AG-2321 PTA First Crystallizer Agitator | Figure 3
2AG-2321 PTA First Crystallizer Agitator | Figure 3
2AG-2321 PTA First Crystallizer Agitator | Figure 4
2AG-2321 PTA First Crystallizer Agitator | Figure 4

The agitator is critical to a line producing about 100 tonnes per hour. Its failure would stop three dependent units. The source lists about two days for dismantling before bearing replacement and a mean time to repair of one week.

6.6 kV Motor Case Study
6.6 kV Motor Case Study | Figure 1
6.6 kV Motor Case Study | Figure 1
6.6 kV Motor Case Study | Figure 2
6.6 kV Motor Case Study | Figure 2

The source document presents these inspection images for a 6.6 kV motor.

Twin Roll Press NDE Bearing | Paper Plant
Twin Roll Press NDE Bearing | Paper Plant | Figure 1
Twin Roll Press NDE Bearing | Paper Plant | Figure 1

The viscose department monitors a high-criticality twin roll press bearing operating at 1.2–2 RPM. The source notes that a failure could interrupt fibre production for 12 hours.

Inspection Case Study | DP World Port
Inspection Case Study | DP World Port | Figure 1
Inspection Case Study | DP World Port | Figure 1
Inspection Case Study | DP World Port | Figure 2
Inspection Case Study | DP World Port | Figure 2
Inspection Case Study | DP World Port | Figure 3
Inspection Case Study | DP World Port | Figure 3
Inspection Case Study | DP World Port | Figure 4
Inspection Case Study | DP World Port | Figure 4

The source document presents these inspection images for the DP World port case.

Raw Mill Movable Roller NDE Bearing | Cement Plant
Raw Mill Movable Roller NDE Bearing | Cement Plant | Figure 1
Raw Mill Movable Roller NDE Bearing | Cement Plant | Figure 1

This case documents inspection of the raw mill movable roller’s non-drive-end bearing.

Switchgear Inspection | 33 kV Breaker
Switchgear Inspection | 33 kV Breaker | Figure 1
Switchgear Inspection | 33 kV Breaker | Figure 1
Switchgear Inspection | 33 kV Breaker | Figure 2
Switchgear Inspection | 33 kV Breaker | Figure 2
Switchgear Inspection | 33 kV Breaker | Figure 3
Switchgear Inspection | 33 kV Breaker | Figure 3

The case compares a good panel with a panel flagged during inspection, then shows findings from the physical inspection of the 33 kV switchgear breaker.

33 kV HT Panel Circuit Breaker
33 kV HT Panel Circuit Breaker | Figure 1
33 kV HT Panel Circuit Breaker | Figure 1
33 kV HT Panel Circuit Breaker | Figure 2
33 kV HT Panel Circuit Breaker | Figure 2

The team used an Ultraprobe 10000 with an SCM and rubber focusing probe at 40 kHz. An 8 dB reading at the rear of the vacuum circuit breaker panel had a tracking-type electrical discharge signature.

33 kV HT Cable Termination
33 kV HT Cable Termination | Figure 1
33 kV HT Cable Termination | Figure 1
33 kV HT Cable Termination | Figure 2
33 kV HT Cable Termination | Figure 2
33 kV HT Cable Termination | Figure 3
33 kV HT Cable Termination | Figure 3
33 kV HT Cable Termination | Figure 4
33 kV HT Cable Termination | Figure 4

An Ultraprobe 15000 survey with an LRM at 40 kHz detected a discharge signature near the Y-phase cable. The report links the finding to crossed R- and Y-phase cables and records a black mark at the R-phase termination.

6.6 kV Switchgear Panel | 2HV32
6.6 kV Switchgear Panel | 2HV32 | Figure 1
6.6 kV Switchgear Panel | 2HV32 | Figure 1
6.6 kV Switchgear Panel | 2HV32 | Figure 2
6.6 kV Switchgear Panel | 2HV32 | Figure 2
6.6 kV Switchgear Panel | 2HV32 | Figure 3
6.6 kV Switchgear Panel | 2HV32 | Figure 3

An inspection using the Ultraprobe 15000 TS identified signs of early-stage corona discharge and vibration associated with looseness on panel 2HV32.

Current Transformer | 110 kV Switchyard
Current Transformer | 110 kV Switchyard | Figure 1
Current Transformer | 110 kV Switchyard | Figure 1

The source document presents this current transformer inspection at a 110 kV switchyard.

33 kV Line | LV-Side Bushing Connector
33 kV Line | LV-Side Bushing Connector | Figure 1
33 kV Line | LV-Side Bushing Connector | Figure 1

The case records a loose LV-side bushing connector with discharge on a 33 kV line.

33/11 kV Switchgear | 11 kV Feeder Panel
33/11 kV Switchgear | 11 kV Feeder Panel | Figure 1
33/11 kV Switchgear | 11 kV Feeder Panel | Figure 1

The source document presents this inspection image for an 11 kV feeder panel.

6.6 kV Enclosed Panel
6.6 kV Enclosed Panel | Figure 1
6.6 kV Enclosed Panel | Figure 1

The source document presents this inspection image for a 6.6 kV enclosed panel.

Internal Discharge | 66/11 kV, 25 MVA Transformer
Internal Discharge | 66/11 kV, 25 MVA Transformer | Figure 1
Internal Discharge | 66/11 kV, 25 MVA Transformer | Figure 1

The case documents internal discharge in a 66/11 kV, 25 MVA transformer.

11 kV Ammonia Plant Pump
11 kV Ammonia Plant Pump | Figure 1
11 kV Ammonia Plant Pump | Figure 1

The source document presents this inspection image for an 11 kV ammonia plant pump.

3.3 kV Pump
3.3 kV Pump | Figure 1
3.3 kV Pump | Figure 1

The source document presents this inspection image for a 3.3 kV pump.

6.6 kV HT Motor | Bearing and Partial Discharge Monitoring
6.6 kV HT Motor | Bearing and Partial Discharge Monitoring | Figure 1
6.6 kV HT Motor | Bearing and Partial Discharge Monitoring | Figure 1

This case covers bearing condition monitoring and electrical partial discharge detection on a 6.6 kV high-tension motor.

E-BOOK

THE PATH TO LUBRICATION EXCELLENCE

This free, comprehensive eBook outlines the best practices in industrial lubrication: why bearings fail prematurely, the different approaches to lubrication practices and how ultrasound technology is fundamental for a world-class lubrication program.

USING ULTRASOUND TO ENHANCE ENERGY EFFICIENCY

Plant managers have many opportunities to improve facility performance, and one of the most impactful places to start is with energy conservation. Evaluating and refining your plant’s energy conservation processes can deliver immediate and long-term benefits. Effective energy management not only reduces operating costs but also supports reliability, efficiency, and overall facility performance.

ACOUSTIC & THERMAL IMAGING

FOTRIC Building Inspection
Thermal view of a building exterior
Thermal view of a building exterior
Thermal view around a window frame
Thermal view around a window frame

Thermal imaging helps inspectors identify surface temperature patterns associated with insulation defects, thermal bridges, air leakage and water seepage. Images can document findings for building quality and energy-efficiency assessments.

FOTRIC Data Centre Solutions
Data centre server racks
Data centre server racks
Thermal and visible views of electrical equipment
Thermal and visible views of electrical equipment

Infrared imaging helps identify hot spots in distribution cabinets, busbars, UPS systems, server racks and cooling equipment. Acoustic imaging complements thermal checks by helping locate signs of partial discharge and air or gas leaks.

FOTRIC Die-Casting Solutions
Die-casting mould
Die-casting mould
Thermal image of a die-casting mould
Thermal image of a die-casting mould

Non-contact thermal imaging measures the temperature distribution across a die surface in real time. Operators can identify hot and cold areas and use the readings to adjust temperature control and improve process consistency.

FOTRIC Equipment Maintenance Solutions
Electrical equipment in visible light
Electrical equipment in visible light
Thermal view of electrical equipment
Thermal view of electrical equipment

Thermal inspections help maintenance teams identify abnormal heating in electrical and mechanical equipment. Comparing thermal patterns across components helps teams flag suspect areas for follow-up before scheduling repairs.

FOTRIC Power Generation Industry Solutions
Power generation facility
Power generation facility
Thermal view of a coal conveyor
Thermal view of a coal conveyor

Thermal imaging helps teams monitor power generation and substation equipment for abnormal heating during operation. The guide covers applications such as coal conveyor monitoring and photovoltaic panel inspection.

FOTRIC Oil Pipeline & Petrochemical Solutions
Petrochemical processing equipment and pipework
Petrochemical processing equipment and pipework
Petrochemical facility
Petrochemical facility

Thermal imaging supports predictive maintenance across petrochemical facilities. The guide covers temperature monitoring for substation equipment, transformers and process equipment, including abnormal heating in oil systems and blockages in coolers.

FOTRIC Thermal Imaging Solutions for Electronics
Thermal image of a circuit board
Thermal image of a circuit board
Temperature trend during an electronics test
Temperature trend during an electronics test

Thermal imaging shows how temperatures change on circuit boards, chips and other electronic components during testing. Teams can use those patterns to locate hot spots, evaluate product stability and support production quality checks.

PARTIDAL DISCHARGE

Astute HV Monitoring to Target Maintenance
Astute HV Monitoring dashboard
Astute HV Monitoring dashboard

Astute monitoring identified partial discharge on an ageing 50-panel switchboard. The team replaced the faulty insulators and continued monitoring. Subsequent ultrasonic readings showed no signs of partial discharge.

Astute Monitoring for Distribution Network Operators
Switchgear damage following the failure
Switchgear damage following the failure

An UltraTEV Monitor recorded rising partial discharge before a switchgear failure. The operator reviewed the readings after an eight-hour outage. The case shows how reviewing trends and acting on alerts can support timely intervention.

Transformer T1 Cable Box Investigation at Sub 16
Transformer cable terminations
Transformer cable terminations

A routine survey detected ultrasonic discharge through the transformer cable box vents. A planned outage allowed the team to inspect the terminations and identify damage around the rear blue-phase cable.

SULB Bahrain | MV Switchgear and Transformer Survey
Damage inside the switchgear
Damage inside the switchgear

An UltraTEV Plus² and UltraTEV Locator survey detected ultrasonic partial discharge at switchgear terminations in a critical 33 kV substation. A subsequent inspection found severe damage to the high-voltage insulation.

SP Energy Networks | Wind Farm Partial Discharge Investigation
UltraTEV Plus² reading during the investigation
UltraTEV Plus² reading during the investigation

SP Energy Networks used the UltraTEV Plus² to interpret high transient earth voltage readings on site. The readings prompted an investigation of the wind farm’s high-voltage network before the fault developed into a failure.

ESB | Targeted Maintenance with Astute HV Monitoring
Insulation from the affected switchgear
Insulation from the affected switchgear

Continuous monitoring helped target maintenance on an ageing switchboard. After faulty insulators were replaced, the system continued collecting data and ultrasonic readings showed no remaining signs of partial discharge.

RWE Renewables | Partial Discharge Detection with UltraTEV Plus²
33 kV equipment inspected during the investigation
33 kV equipment inspected during the investigation

A routine offshore survey recorded high partial discharge. Follow-up testing with the UltraTEV Plus² traced the source to insulation around a faulty 33 kV component.

Trinity Mirror | Partial Discharge on an 11 kV Network
Switchgear component inspected at Trinity Mirror
Switchgear component inspected at Trinity Mirror

At the Watford printing site, the UltraTEV Plus² helped confirm partial discharge from a current transformer. After replacement, a follow-up test confirmed that the discharge source had been eliminated.

Lightsource BP | Cable Termination Faults at a Solar Farm
Cable termination inspected at the solar farm
Cable termination inspected at the solar farm

A routine non-intrusive survey identified high partial discharge readings in substation switchgear. The site team isolated the equipment and dismantled the extensible connector across all three phases to investigate the cable terminations.

Port of Felixstowe | Partial Discharge During Routine Testing
Cable termination damage at the port
Cable termination damage at the port

Routine UltraTEV inspections identified partial discharge at two locations. One affected 11 kV ring main unit had termination damage that required re-termination. The investigation also identified poor connections and insufficient spacing between cable cores.

INEOS Grangemouth | Continuous HV Monitoring
INEOS Grangemouth site
RFCT sensor for continuous partial discharge monitoring

Routine testing at INEOS Grangemouth detected partial discharge at three high-voltage cable joint locations. EA Technology installed radio-frequency current transformers (RFCTs) to monitor the affected circuits while they remained in service. The readings showed no critical deterioration over ten months, allowing INEOS to replace the affected joints during a planned shutdown.

TATA Steel | Investigation of an 11 kV Switchgear Failure
Switchgear examined during the failure investigation
Switchgear examined during the failure investigation

An 11 kV switchgear failure shut down more than 90% of the site. The investigation traced the failure to dust accumulation on bushings, which had led to partial discharge. The team replaced another affected component and updated its maintenance schedule.

SULB Bahrain | 33 kV Switchgear Insulation Findings
Switchgear inspection at an industrial site
Switchgear inspection at an industrial site

The survey identified significant ultrasonic partial discharge at switchgear terminations. Follow-up inspection confirmed severe insulation damage, and the findings prompted intervention at the critical substation.

Abu Dhabi | Proactive High-Voltage Asset Survey
UltraTEV Plus² handheld partial discharge detector
UltraTEV Plus² handheld partial discharge detector

A benchmark survey covered 11 high-voltage switchboards at a hospitality and events venue. Using the UltraTEV Plus² and Locator2, the team identified insulation defects and confirmed a surface discharge issue on one panel.